OPERATION
B–64144EN/01
11. SETTING AND DISPLAYING DATA
657
The current mode, automatic operation state, alarm state, and program
editing state are displayed on the next to last line on the screen allowing
the operator to readily understand the operation condition of the system.
If data setting or the input/output operation is incorrect, the CNC does not
accept the operation and a warning message is displayed on the next to last
line of the screen. This prevents invalid data setting and input/output
errors.
EDIT STOP MTN FIN ALM hh:mm:ss INPUT
––EMG––
(8)
(1) (2) (3)
(4)
(5)
(6) (7)
(Display soft keys)
(9) Data is out of range.
(Note) Actually, this is displayed in the area starting from (2).
(Note) Actually, 5 is displayed in
the area for (3) and (4).
NOTE
Actually, (10) is displayed at the position where (8) is now
displayed.
MDI : Manual data input, MDI operation
MEM : Automatic operation (memory operation)
RMT : Automatic operation (DNC operation, or such like)
EDIT : Memory editing
HND : Manual handle feed
JOG : Jog feed
TJOG : TEACH IN JOG
THND : TEACH IN HANDLE
INC : Manual incremental feed
REF : Manual reference position return
**** : Reset (When the power is turned on or the state in which
program execution has terminated and automatic operation has
terminated.)
STOP : Automatic operation stop (The state in which one block has
been executed and automatic operation is stopped.)
HOLD : Feed hold (The state in which execution of one block has been
interrupted and automatic operation is stopped.)
STRT : Automatic operation start–up (The state in which the system
operates automatically)
MTN : Indicates that the axis is moving.
DWL : Indicates the dwell state.
*** : Indicates a state other than the above.
FIN : Indicates the state in which an auxiliary function is being
executed. (Waiting for the complete signal from the PMC)
*** : Indicates a state other than the above.
11.6.2
Displaying the Status
and Warning for Data
Setting or Input/Output
Operation
Explanations
Description of each display
(1) Current mode
(2) Automatic operation
status
(3) Axis moving
status/dwell status
(4) State in which an
auxiliary function is
being executed