APPENDIXG. ALARM LIST
B–64144EN/01
824
No. DescriptionFaulty location and remedy
SVPM
STATUS1
indica-
tion(*1)
Message
7n20 SPN_n_ : EX OFFSET
CURRENT V
20 Replace the SVPM unit. Abnormality in an SVPM component
is detected. (The initial value of the V
phase current detection circuit is ab-
normal.)
7n21 SPN_n_ : POS SENSOR
POLARITY ER-
ROR
21 Check and correct the parame-
ters.
(No. 4000#0, 4001#4)
The polarity parameter setting of the
position sensor is wrong.
7n24 SPN_n_ : SERIAL
TRANSFER
ERROR
24 1 Place the CNC–to–spindle
cable away from the power
cable.
2 Replace the cable.
The CNC power is turned off (normal
power–off or broken cable).
An error is detected in communication
data transferred to the CNC.
7n27 SPN_n_ : DISCONNECT
POS–CODER
27 Replace the cable. The spindle position coder (connector
JYA3) signal is abnormal.
7n29 SPN_n_ : SHORTTIME
OVERLOAD
29 Check and correct the load status. Excessive load has been applied
continuously for a certain period of
time. (This alarm is issued also when
the motor shaft has been locked in the
excitation state.)
7n30 SPN_n_ : OVERCUR-
RENT POW
CIRCUIT
30 Check and correct the power sup-
ply voltage.
Overcurrent is detected in main circuit
input.
Unbalanced power supply.
7n31 SPN_n_ : MOTOR LOCK 31 Check and correct the load status. The motor cannot rotate at a specified
speed. (A level not exceeding the
SST level for the rotation command
has existed continuously.)
7n32 SPN_n_ : RAM FAULT
SERIAL LSI
32 Replace the SVPM control printed
circuit board.
Abnormality in an SVPM control cir-
cuit component is detected. (The LSI
device for serial transfer is abnormal.)
7n33 SPN_n_ : SHORTAGE
POWER
CHARGE
33 Replace the SVPM unit. Charging the main circuit was not
completed within a prescribed time
period.
7n34 SPN_n_ : PARAMETER
SETTING ER-
ROR
34 Correct a parameter value accord-
ing to the manual.
If the parameter number is un-
known, connect the spindle check
board, and check the indicated pa-
rameter.
Parameter data exceeding the allow-
able limit is set.
7n36 SPN_n_ : OVERFLOW
ERROR
COUNTER
36 Check whether the position gain
value is too large, and correct the
value.
An error counter overflow occurred.
7n37 SPN_n_ : SPEED DE-
TECT PAR.
ERROR
37 Correct the value according to the
parameter manual.
The setting of the parameter for the
number of pulses in the speed detec-
tor is incorrect.
7n41 SPN_n_ : 1–ROT POS–
CODER ER-
ROR
41 1 Check and correct the parame-
ter.
2 Replace the cable.
1 The 1–rotation signal of the spindle
position coder (connector JYA3) is
abnormal.
2 Parameter setting error