APPENDIXG. ALARM LIST
B–64144EN/01
822
The details of spindle alarm No. 750 are displayed in the diagnosis display
(No. 409) as shown below.
#7
409
#6 #5 #4 #3
SPE
#2
S2E
#1
S1E
#0
SHE
#3 (SPE) 0 : In the spindle serial control, the serial spindle parameters fulfill the
spindle unit startup conditions.
1 : In the spindle serial control, the serial spindle parameters do not fulfill
the spindle unit startup conditions.
#2 (S2E) 0 : The second spindle is normal during the spindle serial control startup.
1 : The second spindle was detected to have a fault during the spindle
serial control startup.
#1 (S1E) 0 : The first spindle is normal during the spindle serial control startup.
1 : The first spindle was detected to have a fault during the spindle axis
serial control startup.
#0 (SHE) 0 : The serial communications module in the CNC is normal.
1 : The serial communications module in the CNC was detected to have a
fault.
Alarm List (Serial Spindle)
When a serial spindle alarm occurs, the following number is displayed on
the CNC. n is a number corresponding to the spindle on which an alarm
occurs. (n = 1: First spindle; n = 2: Second spindle; etc.)
NOTE*1
Note that the meanings of the STATUS1 of SVPM
indications differ depending on which LED, the red or yellow
LED, is on. When the red LED is on, the STATUS1 of SVPM
indicates a 2–digit alarm number. When the yellow LED is
on, the STATUS1 of SVPM indicates an error number that
designates a sequence problem (for example, when a
rotation command is entered with the emergency stop state
not released).
³ See “Error Codes (Serial Spindle).”
Alarm Numbers and Alarms Displayed on the STATUS1 of βi series SVPM
No. Message
SVPM
STATUS1
indica-
tion(*1)
Faulty location and remedy Description
(750) SPINDLE SERIAL LINK
ERROR
A0
A
1 Replace the ROM on the
SVPM control printed circuit
board.
2 Replace the SVPM control
printed circuit board.
The program does not start normally.
ROM series error or hardware ab-
normality on the SVPM control printed
circuit board
(749) S–SPINDLE LSI ERROR A1 Replace the SVPM control printed
circuit board.
An abnormality was detected in the
CPU peripheral circuit of the SVPM
control circuit.
D The details of spindle