APPENDIXG. ALARM LIST
B–64144EN/01
812
Number ContentsMessage
233 DEVICE BUSY When an attempt was made to use a unit such as that connected via
the RS–232–C interface, other users were using it.
239 BP/S ALARM While punching was being performed with the function for controlling
external I/O units ,background editing was performed.
240 BP/S ALARM Background editing was performed during MDI operation.
253 G05 IS NOT AVAIRABLE Binary–input operation with a high–speed remote buffer (G05) or
high–speed cycle machining (G05) has been specified in look–ahead
control mode (G08P1). Before attempting to specify these
commands, first specify G08P0; to cancel look–ahead control mode.
5010 END OF RECORD The end of record (%) was specified.
5020 PARAMETER OF RESTART
ERROR
The parameter for specifying program restart is not set correctly.
5073 NO DECIMAL POINT A decimal point is not specified for a command for which a decimal
point must be specified.
5074 ADDRESS DUPLICATION ERROR The same address appears more than once in a block. Alternatively,
a block contains two or more G codes belonging to the same group.
5110 IMPROPER G–CODE
(G05.1 Q1 MODE)
An illegal G code was specified in AI look–ahead control mode.
5111 IMPROPER MODAL G–CODE
(G05.1 Q1)
An illegal G code is left modal when AI look–ahead control mode was
specified.
5112 G08 CAN NOT BE COMMANDED
(G05.1 Q1)
Look–ahead control (G08) was specified in AI look–ahead control
mode.
5114 NOT STOP POSITION
(G05.1 Q1)
At the time of restart after manual intervention, the coordinates at which
the manual intervention occurred have not been restored.
5134 FSSB : OPEN READY TIME OUT The FSSB did not become ready to open during initialization.
5135 FSSB : ERROR MODE The FSSB entered an error mode.
5136 FSSB : NUMBER OF AMPS IS
SMALL
The number of amplifiers recognized by the FSSB is insufficient,
compared with the number of controlled axes.
5137 FSSB : CONFIGURATION ERROR The FSSB detected a configuration error.
5138 FSSB : AXIS SETTING NOT
COMPLETE
Axis setting has not been performed in automatic setting mode. Per-
form axis setting using the FSSB setting screen.
5139 FSSB : ERROR Servo initialization did not terminate normally.
The optical cable may be defective, or there may be an error in connec-
tion to the amplifier or another module.
Check the optical cable and the connection status.
5156 ILLEGAL AXIS OPERATION (AICC) In AI look–ahead control mode, the controlled axis selection signal
(PMC axis control) changes.
In AI look–ahead control mode, the simple synchronous axis selection
signal changes.
5157 PARAMETER ZERO (AICC) Zero is set in the parameter for the maximum cutting feedrate (parame-
ter No. 1422 or 1432).
Zero is set in the parameter for the acceleration/deceleration before in-
terpolation (parameter No. 1770 or 1771).
5197 FSSB : OPEN TIME OUT The FSSB did not open when the CNC had allowed the FSSB to
open.
5198 FSSB : ID DATA NOT READ The initial ID information for the amplifier cannot be read because of
a failure in the temporary assignment.
5212 SCREEN COPY : PARAMETER ER-
ROR
There is a parameter setting error. Check that 4 is set as the I/O channel.
5213 SCREEN COPY : COMMUNICA-
TION ERROR
The memory card cannot be used. Check the memory card. (Check
whether the memory card is write–protected or defective.)