APPENDIXG. ALARM LIST
B–64144EN/01
828
No. DescriptionFaulty location and remedy
SVPM
STATUS1
indica-
tion(*1)
Message
9031 SPN_n_ : MOTOR LOCK 31 Check and correct the load status. The motor cannot rotate at a specified
speed. (A level not exceeding the
SST level for the rotation command
has existed continuously.)
9032 SPN_n_ : RAM FAULT
SERIAL LSI
32 Replace the SVPM control printed
circuit board.
Abnormality in an SVPM control cir-
cuit component is detected. (The LSI
device for serial transfer is abnormal.)
9033 SPN_n_ : SHORTAGE
POWER
CHARGE
33 Replace the SVPM unit. Charging the main circuit was not
completed within a prescribed time
period.
9034 SPN_n_ : PARAMETER
SETTING ER-
ROR
34 Correct a parameter value accord-
ing to the manual.
If the parameter number is un-
known, connect the spindle check
board, and check the indicated pa-
rameter.
Parameter data exceeding the allow-
able limit is set.
9036 SPN_n_ : OVERFLOW
ERROR
COUNTER
36 Check whether the position gain
value is too large, and correct the
value.
An error counter overflow occurred.
9037 SPN_n_ : SPEED DE-
TECT PAR.
ERROR
37 Correct the value according to the
parameter manual.
The setting of the parameter for the
number of pulses in the speed detec-
tor is incorrect.
9041 SPN_n_ : 1–ROT POS–
CODER ER-
ROR
41 1 Check and correct the parame-
ter.
2 Replace the cable.
1 The 1–rotation signal of the spindle
position coder (connector JYA3) is
abnormal.
2 Parameter setting error
9042 SPN_n_ : NO 1–ROT.
POS–CODER
DETECT
42 Replace the cable. The 1–rotation signal of the spindle
position coder (connector JYA3) is
disconnected.
9046 SPN_n_ : SCREW
1–ROT POS–
COD. ALARM
46 1 Check and correct the parame-
ter.
2 Replace the cable.
An abnormality equivalent to alarm 41
was detected during thread cutting
operation.
9047 SPN_n_ : POS–CODER
SIGNAL AB-
NORMAL
47 1 Replace the cable.
2 Correct the cable layout (vicin-
ity of the power line).
1 The A/B phase signal of the
spindle position coder (connector
JYA3) is abnormal.
2 The relationship between the A/B
phase and 1–rotation signal is in-
correct (Pulse interval mismatch).
9050 SPN_n_ : SPNDL CON-
TROL OVER-
SPEED
50 Check whether the calculated val-
ue exceeds the maximum motor
speed.
In spindle synchronization, the speed
command calculation value exceed-
ed the allowable limit (the motor
speed is calculated by multiplying the
specified spindle speed by the gear
ratio).
9051 SPN_n_ : LOW VOLT DC
LINK
51 1 Check and correct the power
supply voltage.
2 Replace the MC.
Input voltage drop was detected.
(Momentary power failure or poor MC
contact)