If the chiller is used in a cold district, it should be provided with an
antifreezing function. When it is extremely cold, the chiller should be
kept running. If it is necessary to use an antifreezing solution for lack of
an alternative, the following antifreezing solution should be used. Its
concentration should be 30% (usually) or 40% (in an extremely cold
district). Use of an antifreezing solution should be restricted within four
months in winter. Do not use antifreezing solution together with an
anticorrosive. The following antifreezing solution is already added with
an anticorrosive.
Product name: AURORA BRINE
Manufacturer: TOKYO FINE CHEMICAL Co.
Use: Refer to the description indicated on the product.
4.4.1.4
Anti–freezing agent