APPENDIX
B–70115EN/03
D. PARAMETERS
398
#7
PS815025
#6
PS7
#5
PS6
#4
PS5
#3
PS4
#2
PS3
#1
PS2
#0
PS1
#7
PS1615026
#6
PS15
#5
PS14
#4
PS13
#3
PS12
#2
PS11
#1
PS10
#0
PS9
PS1 – 16 Discharge tube selection when half of the discharge tubes are used
[How to set] Select desired discharge tubes when half of the discharge tubes integrated
in the oscillator are used. Set the bit for each discharge tube to be used
to 1, and set the other bits to 0.
[Standard setting] Refer to the parameter data sheet delivered with the machine. Set PS9 to
PS16 to 0.
#7
PS815027
#6
PS7
#5
PS6
#4
PS5
#3
PS4
#2
PS3
#1
PS2
#0
PS1
#7
PS1615028
#6
PS15
#5
PS14
#4
PS13
#3
PS12
#2
PS11
#1
PS10
#0
PS9
PS1 – 8 Discharge tube selection when all discharge tubes are used
[How to set] Select desired discharge tubes when all discharge tubes integrated in the
oscillator are used. Set the bits for discharge tubes to be used to 1 in
ascending order of bit numbers, and set the other bits to 0.
[Standard setting] Refer to the parameter data sheet delivered with the machine. Set PS9 to
PS16 to 0.
#7
PS80202
#6
PS7
#5
PS6
#4
PS5
#3
PS4
#2
PS3
#1
PS2
#0
PS1
PS1 – 8 Discharge tube selection when four discharge tubes are used
PS1 – 8 :
Discharge tube selection when the number is 4.
[How to set] Among 4 and 8 tubes four tubes can be selected.
Set the bits for the tubes to use as 1, and others as 0.
[Standard setting] Refer to the parameter data sheet delivered with the machine.
#7
PS80203
#6
PS7
#5
PS6
#4
PS5
#3
PS4
#2
PS3
#1
PS2
#0
PS1
PS1 – 8 Discharge tube selection when six discharge tubes are used
PS1 – 8 :
Discharge tube selection when the number is 8.
[How to set] All the tubes of 8 ones are to be used. Set all the bits as 1.
[Standard setting] Refer to the parameter data sheet delivered with the machine.
D.2
PARAMETERS FOR
DISCHARGE TUBE
SELECTION