B–70115EN/03
4. INSTALLATION
91
2) Set the RUN key to ON to start the oscillator.
3) Perform discharge by setting the HV ON switch to ON. Check that
discharge is performed continuously.
4) Then, perform internal discharge using the settings indicated
below. Two methods of internal discharge are supported. One is
automatic operation based on programming, while the other is
manual operation using switches.
1000 W Duty 30% (C1500B: 15 minutes)
1500 W Duty 50% (C2000B, C2000C: 15 minutes)
2000 W Duty 50% (C3000C, C3000D: 15 minutes)
2500 W Duty 50% (C4000A)
4000 W Duty 30% (C6000B: 15 to 30 minutes)
The frequency is 100 Hz for all of the above.
D Automatic operation
1. Create the following program (when C1500B):
G32 P1 Q1;
G24 S1000 Q50 R900.; S specifies an output (W), Q
G32 P0; specifies a duty cycle (%),
and R specifies a time
(seconds).
2. Lock the shutter, then start the program.
D Manual
This method can be used when the machine operator’s panel has
a switch enabling manual internal discharge.
1) On the setting screen, enter the output power and duty
ratio.
2) Press the internal discharge switch to perform internal
discharge.
5) When a time determined above has elapsed, turn off the RUN ON
key to stop the oscillator. (With the new software, discharge can
be stopped with HV OFF.)
6) Return the discharge gas pressure to the normal setting, and
perform internal discharge with the settings below, then perform
purging.
Parameter No. 15242, No. 15243 (16–L, 16i–L) parameter No. 236
(0–L)
Setting–100 ³ Setting
1500 W Duty 50% (C1500B: 15 minutes)
2000 W Duty 50% (C2000B, C2000C: 15 minutes)
3000 W Duty 50% (C3000C, C3000D: 15 minutes)
4000 W Duty 30% (C4000A: 15 minutes)
4000 W Duty 30% (C6000B: 15 minutes)
The frequency is 100 Hz for all of the above.
7) Repeat step 6) until the output power reaches the specified value
minus 2% or more, and the discharge voltage becomes the
factory–set value plus up to 200 V.
8) Upon the completion of aging, restore the parameter settings to
their original values.