15324 LPSC
LPSC Intra–tube pressure setting at oscillation time for power calibration
coefficient calculation (50 Hz) (valid when EGE = 1)
For an oscillator with an inverter mounted, the same value as parameter
No. 15325 is to be set.
This parameter specifies a value when an oscillator with no inverter
mounted is used in an area where the power supply frequency is 50 Hz.
[Setting range] 0 to 32767
[Unit] 13 Pa
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15325 LPS60C
LPS60C Intra–tube pressure setting at oscillation time for power calibration
coefficient calculation (60 Hz) (valid when EGE = 1)
This parameter specifies a value when an oscillator with an inverter
mounted or an oscillator with no inverter mounted is used in an area where
the power supply frequency is 60 Hz.
[Setting range] 0 to 32767
[Unit] 13 Pa
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15326 LPCD2E
LPCD2E Power command when aging is performed with the automatic aging
function (valid when EGE = 1)
[Setting range] 0 to 7000
[Unit] W
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15327 LECD2E
LFCD2E Oscillation frequency command for aging (valid when EGE = 1)
This parameter specifies a frequency to be used when aging is performed
with the automatic aging function.
[Setting range] 5 to 2000
[Unit] Hz
[Standard setting] 100