B–70115EN/03
6. TROUBLESHOOTING
177
When the machine breaks down, it is necessary to know if the trouble is
in the CNC, PMC, machine or laser.
Even when there does not exist machine failure, the machine might
hang–up for waiting of external signals. Then the check of inside state
of CNC, interface between CNC and PMC, one between laser and CNC
needs to be done.
Here the description is given on the indication of troubles taking place in
laser using the self–diagnostic function of CNC.
The indication of troubles in CNC, PMC as well as machine is described
in the maintenance manual.
FANUC Series 0–L: B–61575E
FANUC Series 16–LA : B–61855E
FANUC Series 16–LB : B–62595EN
FANUC Series 16i–LA : B–63195EN
When the diagnosis function is used, the data indicated below can be
displayed. *** : Series 16–L, 16i–L
[***] : Series 0–L
[PMC→CNC status display]
#7
G220
[G140]
#6 #5 #4
*DU16
#3
*DU8
#2
*DU4
#1
*DU2
#0
*DU1
*DU1 – *DU16 Duty override signal (input)
#7
AGRDYG221
[G145]
#6
CLRDY
#5 #4 #3 #2 #1 #0
AGRDY Assist gas prepared signal (input)
CLRDY Chiller prepared signal (input)
#7
HVONG222
[G146]
#6
RUN
#5
AGST
#4
BEMON
#3
SHTON
#2
SCLON
#1
*BEMLC
#0
*SHTLC
HVON Discharge start signal (input)
RUN Gas pressure control start signal (input)
AGST Assist gas start signal (input)
BEMON Beam on signal (input)
SHTON Shutter open signal (input)
SCLON Guide light on signal (input)
*BEMLC Beam lock signal (input)
*SHTLC Shutter lock signal (input)
6.6
INDICATION OF
STATE BY MEANS OF
SELF DIAGNOSTIC
FUNCTION
6.6.1
Data Items Displayed
on the Diagnosis
Screen