B–70115EN/03
11. LASER OPTICAL SYSTEM
336
To clean the output coupler, follow the procedure given below. Since it
is necessary to touch the optical parts and vacuum parts while cleaning
the output coupler, wear clean gloves or finger cots. Do not touch these
parts with your bare hands.
The output coupler is fabricated using a toxic material. Be careful not to
touch the mirror with your bare hands. If you should touch it, wash your
hands thoroughly under clean running water.
Before starting cleaning, wipe away any foreign matter from around the
parts to be removed. If a removed part is inadvertently soiled, wipe it
clean with ethyl alcohol.
[Procedure]
(1) Turn off the power to the CNC, then open the main circuit breaker or
turn off the power supply of the laser oscillator.
(2) Remove the three beam cover mounting screws (M4 hexagon socket
head bolts), then remove the beam cover.
(3) When the pressure of the vacuum system of the oscillator is lower
than the atmospheric pressure, it may prove impossible to remove the
output coupler. Confirm that the oscillator is in the purge state and
loosen the yellow and orange tube joints to allow the internal pressure
of the vacuum system to equalize with the atmospheric pressure.
If a negative pressure exists in the vacuum system, the atmospheric
pressure sensor must be adjusted. (See Section 9.4.2.)
(4)Slightly loosen the mirror holder screw. Loosen the mirror holder
mounting screw (M4 hexagon socket head bolt), and remove the
mirror holder from the alignment unit.
NOTE
If the O–ring is so tight that the mirror holder cannot be
removed easily, insert the three M4 hexagon socket head
bolts into the beam cover mounting screw holes, and tighten
them evenly. Then, it should be possible to remove the
mirror holder. Note that unevenly tightening the three
screws may damage the O–ring. In this case, coat a small
vaccum grease (Apiezon) to the O–ring of mirror holder.
(5) Remove the output mirror and O–ring from the mirror holder, and
place them on lens cleaning paper. To simply replace the output
coupler at this point, go to step (12).
(6) Place the mirror with its reflecting side (the side facing the discharge
tubes) facing up. Gently blow clean air (using, for example, a camera
blower) across the mirror surface to remove dust and dirt. Drop ethyl
alcohol or lens cleaner onto the mirror surface, moisten a cotton swab
with the fluid, and gently wipe any dirty areas.
(7) Place lens cleaning paper over the mirror, then spray ethyl alcohol or
lens cleaner over the paper and mirror.
11.1.1
Cleaning and
Replacing the Output
Coupler