B–70115EN/03
4. INSTALLATION
100
The laser oscillator incorporates a safety circuit. The safety circuit is
enabled by using a terminal board (XT20).
Figs. 4.4.3.1 (a) to (g) show the cable inlet and the point of connection.
Attach the following cable to the laser oscillator. Also refer to the
applicable NC connection manual.
1) Power supply cable (L1, L2, L3)
Power supply 200 VAC +10% 50/60 Hz "1 Hz, 3f
–15%
Alternatively, 220 VAC +10%, 60 Hz "1 Hz, 3f
–15%
D Cable specifications
Use a four–conductor heavy–duty cable.
Oscillator Conductor cross–sectional area Cable diameter
C1500B 22 mm
2
19 to 32 mm
C2000B
35 mm
2
28 to 38 mm
C2000C
C3000C
C3000D
C4000A 34 to 44 mm
For oscillator C6000B, use four cables having a conductor
cross–sectional area of 100 mm
2
.
2) Grounding cable
There are two grounding locations.
One of the locations is for class–1 grounding.
The other location is for protective grounding. Install a grounding
wire to the location marked “PE.”
3) Interface connection cable
a) I/O signals
D 16–L or 16i–L (one wire)
Connect an optical fiber cable to COP1B or COPI on the
interface PCB.
D 0–L (two wires)
Connect metal cables to CN1 and CN2 on the interface PCB.
b) Emergency stop signals (ESP1 and ESP2)
These signals are not used. Strap the corresponding points.
4.4.3
Electrical Connection
4.4.3.1
NC–to–oscillator
connection and power
supply cable connection