B–70115EN/03
6. TROUBLESHOOTING
142
The alarm number, DGN, and parameter number (PRM NO.) vary with
the CNC model. So, the FS16–L or FS16i–L number comes first, and the
FS0–L number is enclosed in parentheses.
Anomaly of AD converter 1 (Refer to DGN = 981 [844, 845/bit 7])
FS0–L: AD converter 1 on Printed Circuit Board A16B–1212–0270
(CNC side) is not normal.
FS16–L, FS16i–L:
AD converter 1 on Printed Circuit Board A16B–1110–0260
or A16B–2100–0141 (oscillator side)
No. Cause of trouble Solution
1 Anomaly of AD
converter 1
For FS0–L: Replace AD converter 1 installed at
G9 on A16B–1212–0270 (CNC side).
For FS16–L, FS16i–L:
Replace AD converter 1 installed at
C11 on A16B–1110–0260 (oscillator
side).
Replace AD converter 1 installed at
B8 on A16B–2100–0141 (oscillator
side).
2 Anomaly of printed
circuit board
If this alarm is still issued after replacing AD con-
verter 1, replace the following printed circuit board:
For FS0–L: A16B–1212–0270
For FS16–L, FS16i–L:
A16B–1110–0260 or
A16B–2100–0141
Anomaly of AD converter 2 (Refer to DGN = 982 [846, 847/bit 7] )
FS0–L: AD converter 2 on Printed Circuit Board A16B–1212–0270
(CNC side) is not normal.
FS16–L, FS16i–L:
AD converter 2 on Printed Circuit Board A16B–1110–0260
or A16B–2100–0141 (oscillator side) is not normal.
No. Cause of trouble Solution
1 Anomaly of AD
converter 2
For FS0–L: Replace AD converter 2 installed at
J9 on A16B–1212–0270 (CNC side).
For FS16–L, FS16i–L:
Replace AD converter 2 installed at
R11 on A16B–1110–0260 (oscillator
side).
Replace AD converter 2 installed at
D7 on A16B–2100–0141 (oscillator
side).
2 Anomaly of printed
circuit board
If this alarm is still issued after replacing AD con-
verter 2, replace the following printed circuit board:
For FS0–L: A16B–1212–0270
For FS16–L, FS16i–L:
A16B–1110–0260 or
A16B–2100–0141
6.3
RESPONDING TO
ALARM MESSAGES
ON THE SCREEN
Alarm No. 4061 [661]
Alarm No. 4062 [662]