APPENDIX
B–70115EN/03
D. PARAMETERS
418
15240 LEXPS
LEXPS0235
LEXPS Negative pressure in exhaust completion
This is the ultimate vacuu when gas flow system is evacuated in laser
[Starting range] 0 to 32767
[Unit] 13 Pa
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15241 LPIPS
LPIPS0237
LPIPS Intra–tube pressure in discharge start
This is intra–tube gas pressure in discharge preparation completion
(LRDY) state.
[Setting range] 0 to 32767
[Unit] 13 Pa
[Standard setting] 300: C1500B, C2000B
240: C3000C
200: C2000C, C3000D, C4000A, C6000B
15242 LPPS
LPPS Tube pressure for oscillation (50 Hz)
This parameter specifies the gas pressure inside the discharge tube in the
laser oscillation ready state (LSTR).
[Unit] 13 Pa
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15243 LPPS60
LPPS60 Tube pressure for oscillation (60 Hz)
This parameter specifies the gas pressure inside the discharge tube in the
laser oscillation ready state (LSTR).
[Unit] 13 Pa
[Standard setting] Refer to the parameter data sheet delivered with the machine.
D.12
PARAMETERS FOR
GAS CONTROL (1)