APPENDIX
B–70115EN/03
D. PARAMETERS
396
#7
15006
#6 #5 #4
PCL
#3 #2
PIN
#1
TRM
#0
TRM 1 : Disables the start–point and end–point soft keys for the trace setting
screen.
0 : Enables the start–point and end–point soft keys for the trace setting
screen.
PIN 1 : Specifies a G13 address using inch input.
0 : Specifies a G13 address using metric input.
PCL 1 : On–screen pressure display in MPa.
0 : On–screen pressure display in kgf/cm
2
.
#7
RMP15008
#6
EGE
#5 #4 #3
SOC
#2
TAL
#1
GPC
#0
MST
MST When tracing is specified:
1 : If a reference displacement amount is specified with a plus sign, a
movement is made away from the workpiece, and if a reference
displacement amount is specified with a minus sign, a movement is
made toward the workpiece.
0 : If a reference displacement value is specified with a plus sign, a
movement is made toward the workpiece, and if a reference
displacement value is specified with a minus sign, a movement is
made away from the workpiece.
GPC 1 : Tracing control is exercised using a gap amount (distance from the
nozzle to the workpiece).
0 : Tracing control is exercised using a reference displacement amount.
TAL When TRCKM (G225#2) = 1:
1 : Both the tracing out–of–range alarm and the tracing
excessive–displacement alarm are masked.
0 : The tracing out–of–range alarm only is masked.
SOC When the machining condition setting function is used:
1 : A reference displacement amount for tracing control is used as a
reference displacement amount for piercing only during piercing.
0 : A reference displacement amount for tracing control is used as a
reference displacement amount for piercing during operation other
than machining.
EGE 1 : Enables the automatic aging function.
0 : Disables the automatic aging function.
RMP 1 : With the ramping function, a travel distance measurement is made
considering an up/down step distance and specified feedrate value.
0 : With the ramping function, a travel distance measurement is made
considering an up/down step distance.