Title
No.
FANUC Series 16i/18i -MA/MB
AI High Precision Contour Control
FANUC Series 16i -MA/MB
AI Nano High Precision Contour Control
A-78435E
Page
21/
36
Newly registered
Ver Date Design Description
01 01.03.16
Hosokawa
Override to a determined feedrate
The following gives the specifications of override to a feedrate determined by
functions such as deceleration based on feedrate difference in look-ahead
acceleration/deceleration before interpolation and deceleration based on
acceleration rate in AI High Precision Countour Control.
- When bit 3 (OVR) of parameter No. 8459 = 0
The conventional specifications apply.
Override is invalid for deceleration functions such as deceleration based on
feedrate difference and deceleration based on acceleration rate.
- When bit 3 (OVR) of parameter No. 8459 = 1
Override is valid for deceleration functions such as deceleration based on
feedrate difference and deceleration based on acceleration rate.
When bit 3 (OVR) of parameter No. 8459 is 1, the following feedrates can be
overridden:
- Feedrate decelerated by deceleration based on feedrate difference in look-ahead
acceleration/deceleration before interpolation
- Feedrate decelerated by deceleration based on acceleration rate in AI High
Precision Countour Control.
- Feedrate decelerated by deceleration based on acceleration rate in circular
interpolation
- Feedrate decelerated by acceleration clamp in involute interpolation
- Minimum feedrate for deceleration based on acceleration rate in AI High
Precision Countour Control and circular interpolation
- Maximum feedrate of AI High Precision Countour Control.
Even when the feedrate is overridden, the resulting feedrate does not exceed the
maximum cutting feedrate (parameter No. 1422 or No.1430 or No.1432).
Another example of determining the feedrate
If the calculated feedrate exceeds either the upper limit (parameter No. 8465) for
automatic feedrate control that is set for the appropriate parameter or the feedrate
specified with an F command, clamping is performed with the smaller of the
upper limit feedrate and the feedrate specified with the F command.
If the feedrate calculated by the deceleration function based on the acceleration is
smaller than the lower feedrate limit for the deceleration function based on the
acceleration of AI High Precision Countour Control set for parameter No. 19511,
the lower feedrate limit is used for the feedrate. If, however, the specified
feedrate is smaller than the lower feedrate limit, the specified feedrate is used.