6.SAFETY FUNCTIONS OPERATION B-63944EN/02
- 1018 -
6.5.3.3 Workpiece origin offset range setting screen
This screen displays the setting status of workpiece origin offset and
external workpiece origin offset effective data ranges and lets you
change their settings. (Hereinafter, the screen is referred to as the
workpiece origin offset range setting screen.)
Up to six pairs of values can be specified to identify workpiece
coordinate ranges for the workpiece origin offset, and an effective
offset value range can be defined for each of the axes of these six pairs.
As for the external workpiece origin offset, an effective offset value
range can be specified for each axis.
Displaying and setting the workpiece origin offset range setting screen
Procedure
1 Press the
OFFSET
SETTING
function key.
2 Press the
soft key (continuous menu key) at the right edge
of the screen several times until the [GUARD] soft key is
displayed.
3 Click the [GUARD] soft key. The setting screen that was
displayed last with relation to any operation confirmation
function is displayed (the operation confirmation function setting
screen is the first such screen that appears after the system is
restarted).
4 If any screen other than the workpiece origin offset range setting
screen is displayed, click the [WORK] soft key. The workpiece
origin offset range setting screen is displayed.
Workpiece origin offset range setting screen