B-63944EN/02 APPENDIX A.PARAMETERS
- 1533 -
14376
ATR value corresponding to connector 1 on the first separate detector
interface unit
14377
ATR value corresponding to connector 2 on the first separate detector
interface unit
:
14383
ATR value corresponding to connector 8 on the first separate detector
interface unit
14384
ATR value corresponding to connector 1 on the second separate detector
interface unit
:
14391
ATR value corresponding to connector 8 on the second separate detector
interface unit
14392
ATR value corresponding to connector 1 on the third separate detector
interface unit
:
14399
ATR value corresponding to connector 8 on the third separate detector
interface unit
14400
ATR value corresponding to connector 1 on the fourth separate detector
interface unit
:
14407
ATR value corresponding to connector 8 on the fourth separate detector
interface unit
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte
[Valid data range] 0 to 32
Each of these parameters sets the value (ATR value) of the address
translation table corresponding to each connector on a separate
detector interface unit.
The first and second separate detector interface units are connected to
FSSB line 1, and the third and fourth separate detector interface units
are connected to FSSB line 2.
In each of these parameters, set a value obtained by subtracting 1 from
the setting of parameter No. 1023 for the axis connected to a
connector on a separate detector interface unit.
When there is an axis for which bit 1 of parameter No. 1815 is set to 0
to use a separate detector interface unit, set 32 for those connectors
that are not used.