A.PARAMETERS APPENDIX B-63944EN/02
- 1416 -
3410 Tolerance of arc radius
[Input type] Setting input
[Data type] Real path
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 0 to 999999999
When a circular interpolation command is executed, the tolerance for
the radius between the start point and the end point is set.
3411 M code preventing buffering 1
3412 M code preventing buffering 2
:
3420 M code preventing buffering 10
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 0 to 999999999
Set M codes that prevent buffering the following blocks. If
processing directed by an M code must be performed by the machine
without buffering the following block, specify the M code.
M00, M01, M02, and M30 always prevent buffering even when they
are not specified in these parameters.
3421 Range specification 1 of M codes that do not perform buffering (lower limit)
3422 Range specification 1 of M codes that do not perform buffering (upper limit)
3423 Range specification 2 of M codes that do not perform buffering (lower limit)
3424 Range specification 2 of M codes that do not perform buffering (upper limit)
3425 Range specification 3 of M codes that do not perform buffering (lower limit)
3426 Range specification 3 of M codes that do not perform buffering (upper limit)
3427 Range specification 4 of M codes that do not perform buffering (lower limit)
3428 Range specification 4 of M codes that do not perform buffering (upper limit)
3429 Range specification 5 of M codes that do not perform buffering (lower limit)
3430 Range specification 5 of M codes that do not perform buffering (upper limit)
3431 Range specification 6 of M codes that do not perform buffering (lower limit)
3432 Range specification 6 of M codes that do not perform buffering (upper limit)