B-63944EN/02 OPERATION 12.SETTING AND DISPLAYING DATA (15INCH)
- 141 -
4 Input desired data then press the
INPUT
key on the MDI panel to
set the parameter.
5 Press horizontal soft key [INIT]. The standard value
(recommended by FANUC) for the item selected by the cursor is
displayed in the key input buffer. Pressing horizontal soft key
[EXEC] in this state initializes the item to the standard value.
6 Press horizontal soft key [GROUP INIT]. A message asking
whether to set the group standard values is displayed on the screen.
Pressing horizontal soft key [EXEC] in this state inputs all of the
standard values of the group.
NOTE
1 If the cursor is placed on a parameter that has no
standard value assigned, no standard value is input
even when horizontal soft key [INIT] is pressed.
2 When the cursor is placed on multiple bits for bit
parameters, the multiple bits can be input
simultaneously. When horizontal soft key [INIT] is
pressed in this state, the key input buffer displays
the standard values for the bits where the cursor is
placed. If a bit has no standard value assigned, "*"
is displayed for the bit, and no value is input for the
bit.
3 When horizontal soft key [GROUP INIT] is pressed,
those parameters that have no standard values
assigned are not initialized.