B-63944EN/02 APPENDIX A.PARAMETERS
- 1483 -
# 3 ART The retract function executed when a servo spindle alarm is issued is:
0: Disabled.
1: Enabled.
# 6 PHS When the G81/G80 block contains no R command:
0: Acceleration/deceleration is not performed at the start or
cancellation of EGB synchronization.
1: Acceleration/deceleration is performed at the start or cancellation
of EGB synchronization. After acceleration at the start of
synchronization, phase synchronization is automatically
performed.
# 7 PHD The direction of movement for automatic phase synchronization is:
0: Positive (+).
1: Negative (-).
#7 #6 #5 #4 #3 #2 #1 #0
7703 ARO ARE ERV
[Input type] Parameter input
[Data type] Bit path
# 0 ERV During EGB synchronization (G81), feed per revolution is performed
for:
0: Feedback pulses.
1: Pulses converted to the speed for the workpiece axis.
# 1 ARE The retract function executed when a servo spindle alarm is issued
retracts the tool during:
0: EGB synchronization or automatic operation (automatic
operation signal OP = 1).
1: EGB synchronization.
# 2 ARO The retract function executed when a servo spindle alarm is issued
retracts the tool during:
0: EGB synchronization.
1: EGB synchronization and automatic operation (automatic
operation signal OP = 1).
The following table lists the parameter settings and corresponding
operation.
ARE ARO Operation
1 0 During EGB synchronization
1 1
During EGB synchronization and
automatic operation
0 0
0 1
During EGB synchronization or
automatic operation