20.AXIS CONTROL FUNCTIONS PROGRAMMING B-63944EN/02
- 584 -
- One-direction synchronous establishment
When synchronous error compensation is disabled, synchronous
establishment can be performed by setting bit 0 (SSO) of parameter
No. 8305 to 1 to move the machine in one direction along the master
axis and slave axis. The move direction depends on the reference
position setting based on bit 0 (SSA) of parameter No. 8304. When
SSA = 0, for example, the machine coordinate on the master axis or
slave axis, whichever larger, is used as the reference point. So, the
machine moves in the + direction along the axes.
When bit 1 (SSE) of parameter No. 8305 is set to 1, normal
synchronous establishment is performed instead of one-direction
synchronous establishment after an emergency stop.