G.ALARM LIST APPENDIX B-63944EN/02
- 1642 -
(12) Other alarms (DS alarm)
Number Message Description
DS0001 SYNC EXCESS ERROR (POS DEV) In feed axis synchronization control, the difference in the
amount of positional deviation between the master and slave
axes exceeded the parameter (No. 8323) setting value.
This alarm occurs only for the slave axis.
DS0002 SYNC EXCESS ERROR ALARM 1 In feed axis synchronization control, the difference in the
amount of synchronization between the master and slave
axes exceeded the parameter (No. 8331) setting value.
This alarm occurs only for the slave axis.
DS0003 SYNCHRONIZE ADJUST MODE The system is in the synchronize adjust mode.
DS0004 EXCESS MAXIMUM FEEDRATE The malfunction prevention function detected the command
in which a value exceeding the maximum speed was
specified.
DS0005 EXCESS MAXIMUM ACCELERATION The malfunction prevention function detected the command
in which a value exceeding the maximum acceleration was
specified.
DS0014 TOOL CHANGE DETECT MACHINE
LOCK
A machine lock is turned on for the Z axis for which the tool is
being changed.
DS0015 TOOL CHANGE DETECT MIRROR
IMAGE
A mirror image is turned on for the Z axis for which the tool is
being changed.
DS0020 REFERENCE RETURN INCOMPLETE An attempt was made to perform an automatic return to the
reference position on the perpendicular axis before the
completion of a return to the reference position on the
angular axis.
However, this attempt failed because a manual return to the
reference position during angular axis control or an automatic
return to the reference position after power-up was not
commanded. First, return to the reference position on the
angular axis, then return to the reference position on the
perpendicular axis.
DS0024 MISMATCH OF ANGULAR AXIS(D.C.S) On angular axis control, one of the angular/perpendicular
axes is the scale with ref-pos, and the other of them is not
the scale with ref-pos. Such system is not admired.
DS0026 MISMATCH OF ANGULAR AXIS(D.C.S) On angular axis control, one of the angular/perpendicular
axes is the scale with ref-pos, and the other of them is not
the scale with ref-pos. Such system is not admired.
DS0027 MISMATCH OF SYNCHRONOUS
AXIS(D.C.S)
Master/slave axes of feed axis synchronization control, one
of them is the linear scale with distance-coded reference
marks, and the other of them is not the linear scale with
distance-coded reference marks.
Please establish reference position with the input signal
SYNCn<G138>, SYNCJn<G140> or pameter setting to 0.
DS0059 SPECIFIED NUMBER NOT FOUND [External data I/O]
The No. specified for a program No. or sequence No.
search could not be found.
There was an I/O request issued for a pot No. or offset (tool
data), but either no tool numbers have been input since
power ON or there is no data for the entered tool No.
[External workpiece No. search]
The program corresponding to the specified workpiece No.
could not be found.