A.PARAMETERS APPENDIX B-63944EN/02
- 1500 -
Set this parameter for one of the master and slave axes.
When there are multiple slave axes for one master axis, set this
parameter to 1 for an axis with which a synchronization error
excessive alarm is issued for recovery. If an alarm is issued with
multiple axes, modify this parameter after recovery of one axis to
recover another axis.
# 3 CLP In axis feed synchronous control, synchronization error compensation
is:
0: Disabled.
1: Enabled.
Set this parameter with a slave axis.
# 4 MVB In the modification mode, a move command in a direction that
increases a synchronization error is:
0: Ignored.
1: Valid.
When there are multiple slave axes for one master axis, an attempt to
reduce the synchronous error of a slave axis by a movement along the
master axis can increase the synchronization error of another slave
axis. If this parameter is set to 0 in such a case, a movement can be
made in neither direction along the master axis. In this case, set bit 2
(ADJ) of parameter No. 8304 to make a movement along a slave axis
to perform a corrective operation.
# 5 SCA In feed axis synchronous control:
0: Synchronous operation is performed when the feed axis
synchronous control manual feed selection signal SYNCJ or the
feed axis synchronous control selection signal SYNC for slave
axes is set to 1.
1: Synchronous operation is performed at all times.
Set this parameter with a slave axis.
# 6 SMS The synchronization error smooth suppress function is:
0: Disabled.
1: Enabled.
Set this parameter with a slave axis.
# 7 SYE When external machine coordinate system shift is specified by
external data input/output for the master axis in synchronous control,
the slave axis is:
0: Not shifted.
1: Shifted by the same amount as specified for the master axis.
Set this parameter for the slave axis.
This function is disabled during normal operation.