B-63944EN/02 APPENDIX A.PARAMETERS
- 1399 -
Example 2. When No.3012 is set to 5 and No.3019 is set to 5
When XSG (bit 2 of parameter No. 3008) is 1, the PMC axis control skip signal,
measurement position arrival signal, and skip signal are allocated to X0005.
#7 #6 #5 #4 #3 #2 #1 #0
X005 ESKIP -MIT2 +MIT2 -MIT1 +MIT1 ZAE XAE
SKIP
SKIP6 SKIP5 SKIP4 SKIP3 SKIP2 SKIP8 SKIP7
(T series)
#7 #6 #5 #4 #3 #2 #1 #0
ESKIP ZAE YAE XAE
SKIP
SKIP6
SKIP5 SKIP4 SKIP3
SKIP2 SKIP8 SKIP7
(M series)
NOTE
This parameter is valid when bit 2 (XSG) of
parameter No. 3008 is set to 1.
Depending on the option configuration of the I/O
Link, the actually usable X addresses are:
X0 to X127, X200 to X327, X400 to X527, X600 to
X727
3021 Address to which an axis signal is assigned
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 0 to 7, 10 to 17, 20 to 27, ... , 90 to 97
For each axis of the CNC, set a PMC interface address.
Set a value according to the tables below.
Value of parameter No. 3021 (tens digit)
Setting value Input signal address Output signal address
0 G0000 to G0999 F0000 to F0999
1 G1000 to G1999 F1000 to F1999
:
9 G9000 to G9999 F9000 to F9999
Value of parameter No. 3021 (ones digit)
Setting value Input signal address Output signal address
0 #0 #0
1 #1 #1
:
7 #7 #7