B-63944EN/02 PROGRAMMING 17.REAL-TIME CUSTOM MACRO
- 529 -
Linear axis
Metric input
(mm/rev)
Inch input
(inch/rev)
Rotation axis
(deg/rev)
T series 0.001 to 65.535 0.000001 to 0.65535 0.001 to 65.535
M series 0.01 to 500.00 0.0001 to 6.5535 0.01 to 500.00
- Feedrate override
With bit 2 (OVE) of parameter No. 8001, whether to use the
feedrate override signal (*FV) for an NC statement or the
feedrate override signal (*EFV) dedicated to PMC axis control
can be chosen.
NOTE
1 The second feedrate override function cannot be
used.
2 The feedrate override function cannot be disabled
using #3004.
- Override cancel
With bit 2 (OVE) of parameter No. 8001, whether to use the
feedrate override cancel signal (OVC) for an NC statement or the
feedrate override cancel signal (EOVC) dedicated to PMC axis
control can be chosen.
- Operation between blocks
If feed with a specified feedrate is performed in succession in
RTM statements, no stop occurs between blocks, but the next
block is executed. With the accumulated pulse zero check
signal (ELCKZg) for PMC axis control, an accumulated pulse
zero check can be made between blocks specifying feed with a
specified feedrate.
NOTE
1 The error detect signal (SMZ) cannot be used.
2 With the accumulated pulse zero check signal
(ELCKZg) for PMC axis control, an accumulated
pulse zero check can be made between blocks
specifying feed with a specified feedrate for feed on
the same axis only.
- Acceleration/deceleration time constant
For an acceleration/deceleration time constant to be used for feed
with a specified feedrate in an RTM statement when exponential
acceleration/deceleration is used, whether to use the time
constant for an NC statement or the time constant dedicated to
PMC axis control can be chosen using parameter No. 8030.
NOTE
Look-ahead acceleration/deceleration before
interpolation cannot be used.