B-63944EN/02 APPENDIX A.PARAMETERS
- 1491 -
8010 Selection of the DI/DO group for each axis controlled by the PMC
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 1 to 40
Specify the DI/DO group to be used to specify a command for each
PMC-controlled axis.
For addresses of the fifth group and up, 1000 is added in steps of 4
groups.
For example:
The start address of the 10th group is G2154.
The start address of the 25th axis is G6142.
P8010 Description
1 DI/DO 1st group (G142 to G153) is used.
2 DI/DO 2nd group (G154 to G165) is used.
3 DI/DO 3rd group (G166 to G177) is used.
4 DI/DO 4th group (G178 to G189) is used.
5 DI/DO 5th group (G1142 to G1153) is used.
6 DI/DO 6th group (G1154 to G1165) is used.
: :
13 DI/DO 13th group (G3142 to G3153) is used.
: :
20 DI/DO 20th group (G4178 to G4189) is used.
21 DI/DO 21st group (G5142toG5153) is used.
: :
29 DI/DO 29th group (G7142toG7153) is used.
: :
35 DI/DO 35th group (G8166toG8177) is used.
36 DI/DO 36th group (G8178toG8189) is used.
37 DI/DO 37th group (G9142toG9153) is used.
38 DI/DO 38th group (G9154toG9165) is used.
39 DI/DO 39th group (G9166toG9177) is used.
40 DI/DO 40th group (G9178toG9189) is used.
NOTE
When a value other than the above is set, the axis
is not controlled by the PMC.