B-63944EN/02 PROGRAMMING 12.PROGRAM MANAGEMENT
- 277 -
12.3.3 Related Parameters
This subsection lists the meanings of parameters related to program
numbers and the folders and programs to be manipulated or executed.
Parameter
No.
Bit No. Description Manipulation/execution target
0 (NE8)
Disables or enables editing of programs
O8000 to O8999.
Corresponding programs in all folders
3202
4 (NE9)
Disables or enables editing of programs
O9000 to O9999.
Same as above
3 (P8E)
Disables or enables editing of programs
O80000000 to O8999999.
Same as above
4 (P9E)
Disables or enables editing of programs
O90000000 to O99999999.
Same as above
3204
5 (SPR)
Assumes or does not assume a particular
program number in the nine thousands to
be a number obtained by adding 90000000.
Same as above
3210/3211 -
Password/keyword for protecting programs
in the nine thousands
Same as above
3222/3223 -
Program protection range (minimum
value)/(maximum value)
Same as above
3404 2 (SBP)
In the subprogram call function, address P
in the M198 block specifies a file/program
number.
(Not dependent on the folder function and
file name function)
6001 5 (TCS)
Calls or does not call a custom macro by T
code.
The following initial folders can be selected
by parameter setting:
- Common program folder
- MTB dedicated folder 2
- MTB dedicated folder 1
- System folder
6050 to 6059 -
G code for calling a custom macro with
program No. 9010 to 9019
Same as above
6071 to 6079 -
M code for calling a subprogram with
program No. 9001 to 9009
Same as above
6080 to 6089 -
M code for calling a custom macro with
program No. 9020 to 9029
Same as above
6090/6091 -
ASCII code for calling a subprogram with
program No. 9004/9005
Same as above
8341/8343 -
Target program number (for 4- and 8-digit
O number) for sequence number
comparison and stop
Foreground or background default folder
depending on the mode