G.ALARM LIST APPENDIX B-63944EN/02
- 1626 -
Number Message Description
SV0607 CNV. SINGLE PHASE FAILURE PSM : The input power supply has a missing phase.
PSMR : The input power supply has a missing phase.
SV1025 V_READY ON (INITIALIZING ) The ready signal (VRDY) of the velocity control which should
be OFF is ON while the servo control is ON.
SV1026 ILLEGAL AXIS ARRANGE The parameter for servo axis arrange is not set correctly.
A negative value, duplicate value, or greater value than the
number of control axes was set to the parameter No. 1023
"The servo axis number of each axis."
SV1055 ILLEGAL TANDEM AXIS In tandem control, the setting of the parameter No. 1023 is
incorrect.
SV1056 ILLEGAL TANDEM PAIR In tandem control, the setting of the parameter No. 1020, No.
1025, No. 1026 or TDM (No.1817#6) is incorrect.
SV1067 FSSB:CONFIGURATION ERROR(SOFT) An FSSB configuration error occurred (detected by software).
The connected amplifier type is incompatible with the FSSB
setting value.
SV1100 S-COMP. VALUE OVERFLOW The amount of compensation for the straightness exceeded
a maximum value of 32767.
SV5134 FSSB:OPEN READY TIME OUT In the initialization, the FSSB could not be in an open ready
sate. The axis card is thought to be defective.
SV5136 FSSB:NUMBER OF AMP. IS
INSUFFICIENT
The number of amplifier identified by the FSSB is insufficient
than the number of control axes. Or, the setting of the
number of axes or the amplifier connection is in error.
SV5137 FSSB:CONFIGURATION ERROR An FSSB configuration error occurred.
The connecting amplifier type is incompatible with the FSSB
setting value.
SV5139 FSSB:ERROR Servo initialization has not completed successfully. It is
probable that an optical cable failed or a connection between
the amplifier and another module failed.
SV5197 FSSB:OPEN TIME OUT The initialization of the FSSB was completed, but it could not
be opened. Or, the connection between the CNC and the
amplifier in is incorrect.
SV5197 FSSB:OPEN TIME OUT The FSSB could not be opened although the CNC permitted
the opening of the FSSB.
Check the connection between the CNC and the amplifier.
SV5311 FSSB:ILLEGAL CONNECTION 1. This alarm is issued if axes, whose servo axis numbers
(parameter No. 1023) are even and odd numbers, are
allocated to the amplifiers connected to the FSSBs of
different paths.
2. This alarm is issued if an attempt is made to set up for
use of the pulse modules connected to the FSSBs of
different paths. And the system did not satisfy the
requirements for performing HIGH SPEED HRV control.