12.SETTING AND DISPLAYING DATA OPERATION B-63944EN/02
- 1162 -
Procedure to set the axis coordinate to a specified value
Procedure
1 To reset the coordinate to 0, press soft key [ORGIN].
Key in an axis name to be reset (such as X or Y), then press soft
key [EXEC].
2 For presetting to a specified value, key in an axis name to be
preset and a preset value (such as X100.000), then press soft key
[PRESET].
- Display including compensation values
M
Parameters DRL, DRC (No. 3104#4, #5) can be used to select whether
the displayed values include tool length compensation and cutter
compensation.
T
Parameters DRP, DRC (No.3129#0, No.3104#5) can be used to select
whether the displayed values include tool offset and tool nose radius
compensation.
- Presetting by setting a coordinate system
M
Bit 3 (PPD) of parameter No. 3104 can be used to specify whether the
position indication values in the absolute coordinate system are preset
as those in the relative coordinate system during coordinate system
setting or manual reference position return by the G92 command.
T
Bit 3 (PPD) of parameter No. 3104 can be used to specify whether the
position indication values in the absolute coordinate system are preset
as those in the relative coordinate system during coordinate system
setting or manual reference position return by the G50 command (for
G code system A) or G92 command (for G code system B or C).