8. DATA INPUT/OUTPUT (15INCH) OPERATION B-63944EN/02
- 20 -
8.1.6 Inputting and Outputting Custom Macro Common Variables
8.1.6.1 Inputting custom macro common variables
The value of a custom macro common variable is loaded into the
memory of the CNC from a memory card. The same format used to
output custom macro common variables is used for input.
Inputting custom macro common variables
Procedure
1 Make sure the input device is ready for reading.
2 Press the function key
OFFSET
SETTING
.
3 Press the vertical soft key [NEXT PAGE] until the vertical soft
key [MACRO] appears, then press the vertical soft key
[MACRO].
4 Press the EDIT switch on the machine operator’s panel or enter
state emergency stop.
5 Press the horizontal soft key [READ].
6 Type the name of the file that you want to input.
If the input file name is omitted, default input file name
“MACRO.TXT” is assumed.
7 Press the horizontal soft key [EXEC].
This starts reading the custom macro common variables, and
“INPUT” blinks in the lower right part of the screen. When the
read operation ends, the “INPUT” indication disappears.
To cancel the input, press the horizontal soft key [CAN].
Explanation
- Common variables
The common variables (#500 to #549) can be input and output.
(When the option for adding a common variable is specified, values
from #500 to #999 can be input and output.) #100 to #149 can be
input when bit 3 (PV5) of parameter No. 6001 is set to 1. (When the
option for adding a common variable is specified, values from #100 to
#199 can be input and output.)