1.16/18/21-B, 16/18-C MAINTENANCE B-62714EN/04
- 158 -
1.3 SETTING
Setting pin (SH1)
The I/O Link-II board has a setting pin (SH1) mounted. This setting
pin is used for testing at the factory. This setting pin is set before
shipment. Do no change the setting. If the plug is removed, the board
malfunctions.
Rotary switch (SW1-1)
Baud rate setting
The I/O Link-II board has a rotary switch (SW1-1) mounted. This
switch is used for setting a baud rate. This switch is set to 0 before
shipment.
Setting Baud rate
0 1Mbps
CAUTION
The baud rate is to be fixed at 1 Mbps. Do not
change the setting.
Rotary switches (SW2-1, SW3-1)
SW2-1 and SW3-1 are not used. These switches are set to 0 before
shipment.
Rotary switch (SW4-1)
SRAM initialization
The parameters related to the I/O Link-II function are stored in the
SRAM on the I/O Link-II board. When using the I/O Link-II board for
the first time, initialize the SRAM on the board according to the
procedure below.
(1) While the power to the CNC is off, set the rotary switch (SW4-1)
on the board to F.
(2) Turn on the power, and check that the normal CNC screen
appears. (At this time, the SRAM is initialized.)
(3) Turn off the power, then reset SW4-1 from F to 0. Finally, turn
on the power again.