B-62714EN/04 OPERATION 2.LCD-MOUNTED TYPE 16i/18i/21i-A, Power Mate i-D/H
- 47 -
Setting items and display items
Setting items
Table III-2-1
Item Description
MAX SLAVE NO.
Maximum slave station number used for
communication with the master station.
Setting range: 1 to 31
SCAN TIME
Interval for performing one scan of input/output
service. A maximum speed is set automatically
according to [MAX SLAVE NO], so that this parameter
need not be set.
BAUD-RATE
Communication speed.
Setting range: 0 to 3
0: 1.0 Mbps
1: 500 kbps
2: 250 kbps
3: 125 kbps
Two methods of setting are available:
- Input using numeric keys
- Input by soft key selection
(Displayed when the cursor is placed on this
parameter)
STATUS ADDRESS
Start address of an area for storing communication
status.
Setting range: R area of the PMC
The storing of communication status can be disabled
by selecting the soft key [DISABLE] displayed when
the cursor is placed on this parameter.
When the storing of communication status is
disabled, "----" is displayed.
OPTION1 Not used
OPTION2
Successive error detach detection counter.
Recommended setting: 3 [hexadecimal]
Setting range: 00 to FF (hexadecimal)
When the default value 0 is used, the setting of 3 is
assumed for operation.
DO ADDR
DO data area start address.
Setting range: R area of the PMC
DO SIZ
DO data area size.
Setting range: 0 to 128
(Unit: Bytes)
When DO is not used, set 0.
DI ADDR
DI data area start address.
Setting range: R area of the PMC
DI SIZ
DI data area size.
Setting range: 0 to 128
(Unit: Bytes)
When DI is not used, set 0.