2.LCD-MOUNTED TYPE 16i/18i/21i-A, Power Mate i-D/H OPERATION B-62714EN/04
- 68 -
Status of communication with remote slave stations
Status of communication with slave stations #1 to #[MAX SLAVE
NO]:
The status of reception of DO data from each slave station is
indicated (1 byte for each).
bit 7bit 6bit 5bit 4bit 3bit 2bit 1bit 0
Bit 7 : LINK STATUS (status of the link with a remote slave station)
- When LINK STATUS = 0, the link is disconnected.
- When LINK STATUS = 1, communication is performed
normally.
Bits 6 to 0 : Reserved (0 at all times)
Communication status for user visual check of the slave function
User visual check allows the user to visually check communication
status while a network is being built or during operation after a
network is built.
Communication status for user visual check (when DI/DO MAP MODE = 0
[DI/DO data transfer])
This status can be displayed by selecting the soft key [STATUS] on
the slave station setting screen (Screen 2-5).
Screen 2-7
(Screen 2-7 shows that the local slave station (#5) and the master
station are communicating with each other normally.)