3.Power Mate-D/F/H OPERATION B-62714EN/04
- 84 -
0174 Baud rate
[Input type] Parameter input
[Data type] Byte
[Valid data range] 0(Caution)
Set a baud rate.
0: 1 Mbps
CAUTION
The baud rate is fixed at 1 Mbps.
0180 Maximum slave station number from which data is received by the local
station when the global I/O transfer function is used
[Input type] Parameter input
[Data type] Byte
[Valid data range] 0 to 31(Caution)
0: The global I/O transfer function is not used.
1 to 31: The global I/O transfer function is used. Set a maximum
station number from which data is to be received by the local
station.
0181 Internal relay address of the start of DI data
[Input type] Parameter input
[Data type] Word
[Valid data range] 0 to 999
Set the start address of a DI data area (R area of the PMC). This
parameter is valid only when the global I/O transfer function is used.
0182 Internal relay address of the start of DO data
[Input type] Parameter input
[Data type] Word
[Valid data range] 0 to 999
Set the start address of a DO data area (R area of the PMC). This
parameter is valid only when the global I/O transfer function is used.