2.LCD-MOUNTED TYPE 16i/18i/21i-A, Power Mate i-D/H OPERATION B-62714EN/04
- 72 -
When the DPL/MDI operation package of Power Mate i-D/H is used
For the method of using the DPL/MDI operation package, refer to
"FANUC Power Mate i series DPL/MDI Operation Package
Operator's Manual: Supplement (B-63175EN/01-06(03))."
Setting parameters
Set the parameters below when setting the slave function by using the
DPL/MDI operation package with PMi-D/H.
30100 Station number of the local station
[Input type] Parameter input
[Data type] Word
[Valid data range] 1 to 31(Note)
NOTE
When using the global I/O transfer function, set
slave station numbers sequentially to allocate an
area efficiently.
30101 Baud rate
[Input type] Parameter input
[Data type] Word
[Valid data range] 0 to 3
Set a baud rate.
0 : 1 Mbps
1 : 500 kbps
2 : 250 kbps
3 : 125 kbps
30102 Internal relay address of the start of communication status
[Input type] Parameter input
[Data type] Word
[Valid data range] Set 82 as R.
30103 Internal relay offset of the start of communication status
[Input type] Parameter input
[Data type] Word
[Valid data range] -1, 0 to 9999
Set an offset used to allocate communication status.
-1, 0 : Communication status is not allocated.
1 to 9999:Communication status is allocated.