OPERATION
B–63504EN/01
5. TEST OPERATION
435
M, S, and T commands are executed in the machine lock state.
When a G27, G28, or G30 command is issued in the machine lock state,
the command is accepted but the tool does not move to the reference
position and the reference position return LED does not go on.
M00, M01, M02, M30, M98, M99, and M198 (sub–program calling
function) commands are executed even in the auxiliary function lock
state.
Restrictions
D M, S, T command by only
machine lock
D Reference position
return under Machine
Lock
D M codes not locked by
auxiliary function lock