6. FUNCTIONS OF THE MACRO
EXECUTOR
B–62093E–1/02
PROGRAMMING
98
NOTE
1 With the Power Mate–D (two–path control), the PMC axis
control function cannot be used.
2 A control axis is selected by setting the bit of the input signal
G136 or by setting the PMC control axis selection variable
(#8700). Set the bit of G136 on the PMC.
3 The relationships between the areas used and PMC
interface areas are indicated below.
(1) For the Power Mate–D and Power Mate–H
(2) For the Power Mate i–D and Power Mate i–H
4 For details of the PMC axis control interface and so forth,
refer to the connection manual of each model.
Area used PMC interface area
Area A G142 to G149, F130 to F132
Area B G154 to G161, F133 to F135
Area C G166 to G173, F136 to F138
Area D G178 to G185, F139 to F141
Area E G226 to G233, F228 to F230
Area F G238 to G245, F231 to F233
Area used PMC interface area
Area A G142 to G149, F130 to F132
Area B G154 to G161, F133 to F135
Area C G166 to G173, F136 to F138
Area D G178 to G185, F139 to F141
Area E G464 to G471, F500 to F502
Area F G476 to G483, F503 to F505
Area G G488 to G495, F506 to F508
Area H G500 to G507, F509 to F511
(1) Control codes
(a) Rapid traverse command (G340)
G340 Xxxx;
The rapid traverse command is issued to the PMC control axis.
Specify the incremental traveling distance after address X.
(b) Cutting feed command (G341)
G341 Xxxx Ffff;
The cutting feed command is issued to the PMC control axis.
Specify the incremental traveling distance after address X.
Specify the feedrate after address F.
(c) Dwell command (G344)
G344 Pxxx:
The dwell command is issued to the PMC control axis. Specify
the dwell time after address P.