2. MACRO COMPILER AND
MACRO EXECETOR
B–62093E–1/02
PROGRAMMING
18
(c) For the Power Mate–H, Power Mate i–D, and Power Mate i–H
MACRO COMPILER/EXECUTOR P–CODE LOADER
(I/O PARAMETERS) (DATA TRANSFER)
ADRxxxxxxH:xx
I/O CHANNEL = 0 (MAPPING–128KB)
I/O UNIT = 0 * ______________
BAUDRATE =11 _______________
STOP BIT = 1 _______________
INPUT CODE = 1 _______________
_______________
(ERROR OCCURED) _______________
ILLEGAL CHARACTER _______________
_______________
LOADING RESTART ? : YES (PUSH 1 KEY)
: NO (PUSH CAN KEY)
(Note)
When the numeric key 1 is pressed, the screen display returns to
the screen for procedure (5) to start loading again.
When the MDI key (CAN) is pressed, the Power Mate terminates
the P–code loader function, and starts up.
If an error such as a Power Mate communication parameter
setting error is found, however, the Power Mate must be started
up by terminating the P–code loader function, then the error must
be corrected on the parameter screen.
NOTE
With the Power Mate i–D and Power Mate i–H, a mapping
size of 256K bytes is indicated.
(10) If the macro executor option is not selected, the screen shown below
appears when the P–code loader function is started. In this case, the
P–code loader function cannot be used.
(a) For the Power Mate–D
MACRO COMPILER/EXECUTOR P–CODE LOADER
(I/O PARAMETERS) (DATA TRANSFER)
ADR000000H:00
I/O CHANNEL = 0 (MAPPING–128KB)
I/O UNIT = 0 * ______________
BAUDRATE =11 _______________
STOP BIT = 1 _______________
INPUT CODE = 1 _______________
_______________
EXECUTOR OPTION NOTHING
PLEASE TURN OFF POWER
Turn off the power to the Power Mate.