B–62093E–1/02
2. MACRO COMPILER AND
MACRO EXECUTOR
PROGRAMMING
21
(7) When the Power Mate receives data, the state of data reception is
displayed as shown below.
DATA TRANSFER
ADRXXXXXXH:
X : Transfer address (updated every 10 hours)
: Transferred data
(8) When loading is completed successfully, the screen below appears.
(a) For the Power Mate–D
LOADING END
START? (PUSH 1)
When the numeric key 1 is pressed, the Power Mate terminates
the P–code loader function, and starts up.
(b) For the Power Mate–D (two–path control)
LOADING END /1
RETURN (PUSH 1)
When the numeric key 1 is pressed, the screen display returns to
the path selection screen for procedure (4).
(c) For the Power Mate–H
TO F–ROM? (PUSH 1)
ELSE (PUSH CAN)
When the numeric key 1 is pressed, transferred data is written to
flash–ROM.
When the MDI key (CAN) is pressed, or data has been written to
flash–ROM, the screen below appears.
COMPLETE
START? (PUSH 1)
When the numeric key 1 is pressed, the Power Mate terminates
the P–code loader function, and starts up.
(9) If an error occurs during loading, the screen below appears.
(a) For the Power Mate–D
LOAD ERR02
RETRY?(PUSH CAN)
(Alarm message)
When the MDI key (CAN) is pressed, the screen display returns
to the screen for procedure 5 to start loading again.
If an error such as a Power Mate communication parameter
setting error is found, however, the power must be turned off then
back on, then the error must be corrected on the parameter screen.