H. PARAMETERS
B–62093E–1/02
APPENDIX
214
#7 #6 #5 #4 #3 #2 #1 #0
9000 L2R MKG RSC EXS STP NDP SQN
SQN 0 : Displays program number and sequence number of called
user program during execution of a recorded program.
1 : Displays program number of recorded program and
sequence number during execution of a recorded program.
NDP 0 : Does not display variables for P–CODE program.
1 : Displays variables for P–CODE program.
STP 0 : Execute the conversational macro program.
1 : Stops execution of conversational macro program. (”1” is
set by break function automatically)
EXS 0 : Stop if feed hold acts, during macro statement execution at
execution level.
1 : Execute macro statement till the next NC statement has
come with feed hold, during macro statement execution at
execution level.
RSC 0 : Common variables #100–#149 do not clear to <vacant> if
NC is reset.
1 : Common variables #100–#149 are cleared to <vacant> if
NC is reset.
MKG : Be sure to set to 0.
L2R 0 : Display conversational / auxiliary macro and screen during
execution macro operation.
1 : Does not display conversational / auxiliary macro and
screen during execution macro operation.
9002 Conversational macro break program number
9003 Conversational macro break sequence number
#7 #6 #5 #4 #3 #2 #1 #0
9010 MA8 MA7 MA6 MA5 MA4 MA3 MA2 MA1
MA1 0 : Does not mask a first axis address macro call.
1 : Masks a first axis address macro call.
MA2 0 : Does not mask a second axis address macro call.
1 : Masks a second axis address macro call.
MA3 0 : Does not mask a third axis address macro call.
1 : Masks a third axis address macro call.
MA4 0 : Does not mask a fourth axis address macro call.
1 : Masks a fourth axis address macro call.
MA5 0 : Does not mask a fifth axis address macro call.
1 : Masks a fifth axis address macro call.
MA6 0 : Does not mask a sixth axis address macro call.
1 : Masks a sixth axis address macro call.
MA7 0 : Does not mask a seventh axis address macro call.
1 : Masks a seventh axis address macro call.
MA8 0 : Does not mask an eighth axis address macro call.
1 : Masks an eighth axis address macro call.
H.2
EXECUTOR
PARAMETER