B–62093E–1/02
H. PARAMETERS
APPENDIX
209
Examples) GOTO #101;
M99 P100;
#7 #6 #5 #4 #3 #2 #1 #0
9002 EXT1 PWSR DAUX XDIL EVF ACL2 ACL1 TCAL
TCAL 0 : Makes invalid the sub–program call with T code
1 : Makes effective the sub–program call with T code
ACL1 0 : Makes invalid call by the specific code
1 : Makes effective call by the specific code (O9004/#146)
ACL2 0 : Makes invalid call by the specific code
1 : Makes effective call by the specific code (O9005/#147)
EVF 0 : Extension P–CODE variable #20000 is the floating
decimal point format
1 : Extension P–CODE variable #20000 is the fixed decimal
format
XDIL 0 : Axis interlock function invalid
1 : Axis interlock function valid
DAUX 0 : Does not make the CUSTOM screen appear at power on
1 : Makes CUSTOM screen appear at power on
PWSR 0 : P CODE work number search function invalid
1 : P CODE work number search valid
EXT1 0: Extension functions invalid
1: Extension functions valid (RS–232–C control, NC
program access)
NOTE
When EXT1 = 1, part program memory reduces by 1.63 m
for Power Mate–D, Power Mate–D (2–path control), and
Power Mate–H.
#7 #6 #5 #4 #3 #2 #1 #0
9003 PTCR KY20 ONMSK
ONMSK 0 : The O and N numbers are displayed on the CUSTOM
screen.
1 : The O and N numbers are not displayed on the CUSTOM
screen.
KY20 0 : Not +20 to #8501 with decimal point input by key input
variables
1 : +20 to #8501 with decimal input by key input variables
PTCR 0 : Does not output ”CR” code twice in P–CODE variable
outputting
1 : Output ”CR” code twice in P–CODE variable outputting