6. FUNCTIONS OF THE MACRO
EXECUTOR
B–62093E–1/02
PROGRAMMING
104
This function allows the signals of the system variables of the P–CODE
program (UI: #1000 to #1015, #1032, UO: #1100 to #1115, #1132) to
be different from those of the user program.
When the program is compiled with parameter DIOC (No. 9006, #0) set
to 1, UI and UO of the P–CODE program (execution, conversational, or
auxiliary macro) correspond to the following interface signals. Even
when this function is used, UI and UO of a user–created custom macro
program correspond to ordinary interface signals.
Input signal Output signal
#1000 : EUI00 #1100 : EUO00
#1001 : EUI01 #1101 : EUO01
#1002 : EUI02 #1102 : EUO02
::
#1015 : EUI15 #1115 : EUO15
#1032 : EUI00–EUI15 #1132 : EUO00–EUO15
PMC interface
Input signal
76543210
EUI07 EUI06 EUI05 EUI04 EUI03 EUI02 EUI01 EUI00
EUI15 EUI14 EUI13 EUI12 EUI11 EUI10 EUI09 EUI08
Output signal
76543210
EUO07 EUO06 EUO05 EUO04 EUO03 EUO02 EUO01 EUO00
EUO15 EUO14 EUO13 EUO12 EUO11 EUO10 EUO09 EUO08
6.21
FUNCTION FOR
SEPARATING UI
FROM UO OF THE
P–CODE PROGRAM
G082
G083
F084
F085