B–62093E–1/02
2. MACRO COMPILER AND
MACRO EXECUTOR
PROGRAMMING
17
(9) If an error occurs during loading, the screen below appears.
(a) For the Power Mate–D
MACRO COMPILER/EXECUTOR P–CODE LOADER
(I/O PARAMETERS) (DATA TRANSFER)
ADRxxxxxxH:xx
I/O CHANNEL = 0 (MAPPING–128KB)
I/O UNIT = 0 **********_____
BAUDRATE =11 _______________
STOP BIT = 1 _______________
INPUT CODE = 1 _______________
_______________
(ERROR OCCURED) _______________
ILLEGAL CHARACTER _______________
_______________
LOADING RESTART ? : YES (PUSH CAN KEY)
: NO (TURN OFF POWER)
When the MDI key (CAN) is pressed, the screen display returns
to the screen for procedure 5 to start loading again.
If an error such as a Power Mate communication parameter
setting error is found, however, the power must be turned off then
back on, then the error must be corrected on the parameter screen.
(b) For the Power Mate–D (two–path control)
MACRO COMPILER/EXECUTOR P–CODE LOADER
SYSTEM: HEAD 1
(I/O PARAMETERS) (DATA TRANSFER)
ADRxxxxxxH:xx
I/O CHANNEL = 0 (MAPPING–128KB)
I/O UNIT = 0 * ______________
BAUDRATE =11 _______________
STOP BIT = 1 _______________
INPUT CODE = 1 _______________
_______________
(ERROR OCCURED) _______________
ILLEGAL CHARACTER _______________
_______________
LOADING RESTART ? : YES (PUSH CAN KEY)
: NO (TURN OFF POWER)
When the MDI key (CAN) is pressed, the screen display returns
to the path selection screen for procedure 4. If an error such as
a Power Mate communication parameter setting error is found,
however, the Power Mate must be started up by terminating the
P–code loader function, then the error must be corrected on the
parameter screen.