B–62093E–1/02
2. MACRO COMPILER AND
MACRO EXECUTOR
PROGRAMMING
13
(5) When a Power Mate model other than the PM–D (two–path control)
is used, or a path is selected with the PM–D (two–path control), the
memory of the macro executor is initialized. When the memory has
been initialized, the loading screen shown below appears.
MACRO COMPILER/EXECUTOR P–CODE LOADER
SYSTEM:HEAD 1
(I/O PARAMETERS) (DATA TRANSFER)
I/O CHANNEL = 0 (MAPPING–128KB)
I/O UNIT = 0
BAUDRATE =11
STOP BIT = 1
INPUT CODE = 1
LOADING READY ? : YES (PUSH 1 KEY)
Only when the PM–D (two–path control) is used, a path name
is displayed. A path name indication also appears on the
subsequent screens.
(6) When a preparation for data transfer has been made on the P–G or
personal computer, press the numeric key 1. Then, the screen below
appears to wait for P–code transfer. When this screen is displayed,
execute a data transfer command on the P–G or personal computer
to start data transfer.
MACRO COMPILER/EXECUTOR P–CODE LOADER
(I/O PARAMETERS) (DATA TRANSFER)
ADR000000H:00
I/O CHANNEL = 0 (MAPPING–128KB)
I/O UNIT = 0 ________________
BAUDRATE =11 ________________
STOP BIT = 1 ________________
INPUT CODE = 1 ________________
________________
________________
________________
________________
When transferring data from the P–G, see Section 2.1.4.
When transferring data from the personal computer, specify the
following command:
A:¥>MTRNSC <filename> <parameters>
<filename>
Specify a ROM format file to be transferred.