E. DIFFERENCES BETWEEN Series 0 AND
Power Mate
B–62093E–1/02
APPENDIX
194
Signed values consisting of 1 to 4 bytes can be written.
G310 Dd Lȏ Qq ;
G310 Rr Lȏ Qq ;
G310 Cc Lȏ Qq ;
G310 Kk Lȏ Qq ;
D: Data table number of the PMC
R: Internal relay number of the PMC
C: Counter
K: Keep relay
L : Data length (1 or blank: 1 byte, 2: 2 bytes, 4: 4 bytes)
⇒ Unsigned when L is not specified. Signed when L is 1.
Q: Write data (Converted to binary when transferred)
Signed values consisting of 1 to 4 bytes can be read.
G310 Dd Pp Lȏ ;
G310 Rr Pp Lȏ ;
G310 Cc Pp Lȏ ;
G310 Kk Pp Lȏ ;
D: Data table number of the PMC
R: Internal relay number of the PMC
C: Counter
K: Keep relay
P : Number of the variable in which the read data is stored.
L : Data length (1 or blank: 1 byte, 2: 2 bytes, 4: 4 bytes)
⇒ Unsigned when L is not specified. Signed when L is 1.
⇒ The value is handled using two’s complement.
Window function is not exist for Power Mate–D, Power Mate–D (2–path
control), and Power Mate–H.
E.4
PMC WRITE
CONTROL CODE
E.5
PMC READ
CONTROL CODE
E.6