B–62093E–1/02
2. MACRO COMPILER AND
MACRO EXECUTOR
PROGRAMMING
25
Alarm message for
CRT/DPL
Description/cause
ILLEGAL CHARACTER
LOAD ERR00
Data transferred is incorrect.
OVERRUN
LOAD ERR
01
Overrun error
FRAMING ERROR
LOAD ERR
02
Framing error
ILLEGAL CHANNEL
LOAD ERR
03
A channel other than channel 1 is selected.
DSR SIGNAL OFF
LOAD ERR
04
Communication error
PARITY ERROR
LOAD ERR
05
Data with no parity was transferred.
EXECUTOR OPTION NOTHING
LOAD ERR
06
(OPTION NOTHING)
The macro executor option is not selected.
CHECK SUM ERROR
LOAD ERR
08
Checksum error
ILLEGAL MACRO LIBRARY
LOAD ERR
09
A mismatching macro library is used. Use a
matching macro library.
MEXE NOT FOUND
LOAD ERR
10
The executor section is missing. Load data in-
cluding the executor section.
FILE SIZE OVER
LOAD ERR
11
The size of P–code to be loaded exceeds the
size of D–RAM.
HEADER NOT FOUND
LOAD ERR
12
Header information for writing to F–ROM can-
not be found.
In the transfer command MTRNSC, –S may not
be specified.
ILLEGAL ID INFORMATION
LOAD ERR
14
F–ROM file identification information is invalid.
NO SPACE
LOAD ERR
15
There is no write area in the F–ROM module.
ERASE ERROR
LOAD ERR
16
An attempt to erase F–ROM failed.
The F–ROM device may be faulty.
PROGRAM ERROR
LOAD ERR
17
An attempt to write to F–ROM failed.
The F–ROM device may be faulty.
2.1.6.5
Alarms