B–62093E–1/02
2. MACRO COMPILER AND
MACRO EXECUTOR
PROGRAMMING
23
(1) As the loading I/O channel, use channel 1.
(2) ASCII or ISO code is transferred. EIA code is not used.
Whether to use ASCII or ISO is determined by bit 3 (ASI) of
parameter No. 0101, No. 0111, and No. 0121.
(3) The I/O parameters displayed on the loading screen indicate the
settings of the RS–232–C related parameters of (1) and (2) above.
On this screen, no parameter can be set.
(4) Even if bit 1 (PCODE) of parameter No. 8701 for overwrite loading
is set to 1, whether data transferred includes the P–code section only
or includes the executor section as well is determined by macro
compiler operation.
(5) When loading is to be performed for the first time (including a case
where the executor area is initialized), be sure to set bit 1 (PCODE)
of parameter No. 8701 to 0 to transfer data including the executor
section.
No.
0020 I/O device selection I/O CHANNEL
Setting input enabled
Data type : Byte
Valid data range : 0 to 2
Selects an I/O device to be used.
0 : Selects the device of channel 1.
1 : Selects the device of channel 1.
2 : Selects the device of channel 2.(*)
NOTE
Channel 2 can be used only with the Power Mate i–D and
Power Mate i–H.
(1) When I/O CHANNEL = 0 (parameter No. 0020 = 0)
#7 #6 #5 #4 #3 #2 #1 #0
No.
0101 ASI SB2
Data type: Bit
SB2 : The number of stop bits is:
0 : 1 bit
1 : 2 bits
ASI : Data input code is:
0 : ISO code
1 : ASCII code
NOTE
EIA code cannot be used with the P–code loader function.
2.1.6.3
Notes
2.1.6.4
Parameters