B–62093E–1/02
H. PARAMETERS
APPENDIX
211
#7 #6 #5 #4 #3 #2 #1 #0
9006 CNCHG DAUXR STDM KEYC DIOC
DIOC 0 : Standard UI:G54/G55 and UO:F54/F55 are used for
UI/UO(#1000–#1132) of execution macro/ conversational
macro.
1 : UI:G82/G83 and UO:F84/F85 are used for UI/UO
(#1000–#1132) of execution macro/ conversational macro.
KEYC 0 : When KEY switch =0, completion code #8529=254 in an
access to NC program
1 : KEY switch is not cheched in an access to NC program
STDM 0 : The mode and status display is changed on the USER–1,
USER–2, and USER–3 screens on which the
conversational macro screen is displayed.
1 : The mode and status display is left unchanged on the
USER–1, USER–2, and USER–3 screens on which the
conversational macro screen is displayed.
DAUXR : The conversational macro screen is displayed when power
is turned on while the system is in the emergency stop state
or external reset state.
(Parameter DAUX (No. 9002, #5) must also be set to 1.)
CNCHG : Execution of the conversational macro is continued when
the
CUSTOM
key is pressed while the conversational macro
screen is displayed.
#7 #6 #5 #4 #3 #2 #1 #0
9007 TIVR1
TTVR1 : Common conversational macro variables (#10000 to
#19999) are specified.
(1: For variables #10000 to #19999, areas #10000 to
#19999 of the other head are used.)
#7 #6 #5 #4 #3 #2 #1 #0
9008 MCARG AX8CL AX7CL AX6CL AX5CL
AX5CL 0 : Subprogram call by the 5th axis address is made invalid.
1 : Subprogram call by the 5th axis address is made valid.
AX6CL 0 : Subprogram call by the 6th axis address is made invalid.
1 : Subprogram call by the 6th axis address is made valid.
AX7CL 0 : Subprogram call by the 7th axis address is made invalid.
1 : Subprogram call by the 7th axis address is made valid.
AX8CL 0 : Subprogram call by the 8th axis address is made invalid.
1 : Subprogram call by the 8th axis address is made valid.
MCARG 0 : In macro calling of G/M codes, P/L/N/G is not argument.
1 : In macro calling of G/M codes, P/L/N/G is argument.