2.ALARM NUMBERS AND BRIEF DESCRIPTIONS TROUBLESHOOTING B-65285EN/03
- 84 -
Alarm No. SPM PSM Description Remarks
9075 7n75 75 CRC test alarm 3.4.36
9076 7n76 76 Safety function not executed 3.4.37
9077 7n77 77 Axis number mismatch 3.4.38
9078 7n78 78 Safety parameter mismatch 3.4.39
9079 7n79 79 Abnormal initial test operation 3.4.40
9081 7n81 81 Motor sensor one-rotation signal detection error 3.4.41
9082 7n82 82 Motor sensor one-rotation signal not detected 3.4.42
9083 7n83 83 Motor sensor signal error 3.4.43
9084 7n84 84 Spindle sensor disconnected 3.4.44
9085 7n85 85 Spindle sensor one-rotation signal detection error 3.4.45
9086 7n86 86 Spindle sensor one-rotation signal not detected 3.4.46
9087 7n87 87 Spindle sensor signal error 3.4.47
9088 7n88 88 Cooling fan stopped of the radiator 3.4.48
7n97 Other spindle amplifier alarm 3.4.52
7n98 Other converter alarm 3.4.52
749 A Program ROM error 3.4.49
749 A1 Program ROM error 3.4.49
749 A2 Program ROM error 3.4.49
9110 7n98 b0 Communication error between amplifier and module 3.4.50
9111 7n98 b1 6 Converter: control power supply low voltage 3.1.6
9112 7n98 b2 8 Converter: excessive regenerative power 3.1.8
9113 7n98 b3 A Converter: cooling fan stopped of the radiator 3.1.9
9120 C0 Communication data alarm 3.4.51
9121 C1 Communication data alarm 3.4.51
9122 C2 Communication data alarm 3.4.51
9123 C3 Spindle switching circuit error 3.4.52
756, 766 Abnormal axis data 3.4.51
* n represents a spindle number.